Arming Control Unit
rule

The Arming Control Unit (ACU-7) is used to open/close (arm/disarm) an area of alarm zones for one or more designated field devices in the Integrated Digital Controllers (IDC) System.

Each ACU-7 can be configured to control one account when the field devices are connected to the same Network Local Controller (NLC). Up to fifteen (15) ACU-7 units can be interfaced to a single NLC. Each ACU-7 communicates with the NLC/COMM via a 22 AWG, 2-wire twisted pair cable using standard 2-wire RS-485 communications.

The ACU-7 uses an unmarked keypad in combination with a four-line, 80-character Liquid Crystal Display (LCD) for security code entry and data selection. Six unlabeled “soft” keys are located above and six below the LCD. In some modes of operation five of the keys above and below represent the numeric keys (0 – 9). These keys may be labeled in four different methods; horizontal (1,2,3,4,5 on top, and 6,7,8,9,0 on bottom), vertical (1,3,5,7,9 on top and 2,4,6,8,0 on bottom) or, for higher security, Rotational and Rotational-PLUS.

The Rotational method presents a new arrangement of number assignments to the keys for each use. The Rotation-Plus presents a new arrangement of number assignments to the keys after each keystroke. In either Rotational modes the keys are always shown in numerical order, similar to the horizontal method, however the starting point is always different and randomly determined.

This dynamic keypad labeling makes available the following ACU-7 functions:

  • Provides functionally unified system of access control, alarm monitoring and facility controls

  • OPEN or CLOSE account (requires entry of a 5-digit "user" security code)

  • Display Account Status: OPEN, CLOSED, ENTRY DELAY or EXIT DELAY

  • Display Status for up to 64 zones in the account on one screen: SAFE, ACTIVE ALARM or FAULT, ACTIVE ALARM and MASKED, SAFE and MASKED

  • Display ACTIVE ALARMS only (one at a time) with full descriptive text name

  • Display MASKED ZONES only (one at a time) with full descriptive text name

  • Display CURRENT TIME or REMAINING OPEN TIME (hh:mm:ss)

  • ARM, DISARM, MASK, UNMASK individual alarm points, and FORCE CLOSE ACCOUNT with alarm points masked (requires entry of a 5-digit ìprivileged userî security code)

Mounting Diagram



 

Technical Specifications
ELECTRICAL
  Power 12 Volts DC ±10%, 80mA maximum
DIMENSIONS
  Height 4.25 in. (108 mm)
  Width 8.0 in. (203 mm)
  Depth 1.0 in. (25 mm)
MATERIAL
  Panel Die cast aluminum, gray
  Back Box Aluminum frame
  Mounting Mounts to 2-gang, 3-gang or 4-gang electrical box
ENVIRONMENT
  Temperature 32ºF-120ºF, (0ºC-50ºC)
  Humidity 10%-95% (non-condensing)
COMMUNICATIONS
  Protocol RS-485
  Distance 4,000 feet (1300m)
  Media Type Twisted Pair (Beldon 9841 cable)
KEYPAD
  Type Individual pushbuttons provide positive tactile feedback
  Format 12 keys – six keys in a row above display and six below display
  Function All functions and digits are dynamically labeled and located
DISPLAY
  Type Liquid Crystal Display (LCD)
  Format 80 characters, 4 lines of 20 characters
  Back Light Green LED array, always on
ANNUNCIATOR
  Internal Beeper Sounds on each keypad entry
CERTIFICATIONS
  Pending: FCC

Design and specifications subject to change without notice.